The home building industry is ruled by codes but the international residential code doesn t have a requirement for swing direction.
Bc building code door swing.
The bc building code bcbc is a provincial regulation that governs how new construction building alterations repairs and demolitions are completed.
The rule of thumb is to hang interior doors to open into the room not out into a hallway or other common area.
On july 1 2017 sentence 9 9 6 5 1 of division b of the regulation is amended by striking out single dwelling unit and.
We have a room in the parking garage in the lower floor of our multi unit building that holds storage lockers for all of the units.
The bc plumbing code book ii of the bc building code applies to the design construction extension alteration renewal or repair of plumbing systems.
During its swing any door in a means of egress shall leave unobstructed at least one half of the required width of an aisle corridor passageway or landing nor project more than 7 inches 178 mm into the required width of an aisle corridor passageway or landing when fully open.
We had always assumed that when room capacity reaches 50 people the room needs 2 exit doors and the doors must swing out.
I have a question about the bc building code i was hoping to get some insight on.
The door assembly shall have an integrated standby power supply.
Door swing bc building code question.
But reading between the lines section 1008 1 2 says doors shall swing in the direction of egress travel where serving an occupant load of 50 or more.
This code establishes minimum requirements for safety health accessibility fire and structural protection of buildings and energy and water efficiency.
The code requires panic hardware or fire exit hardware for doors serving an occupant load of 50 or more in a group a or e.
Building codes for exterior doors.
The ontario building code direction of door swing 9 9 6 5.
The door assembly shall comply with the applicable fire protection rating and where rated shall be self closing or automatic closing by smoke detection in accordance with section 715 4 8 3 shall be installed in accordance with nfpa 80 and shall comply with section 715 of this code.
Exterior doors in homes and businesses not only provide security but they also serve as a vital means of egress during a fire or other emergency.
Direction of door swing 1 except as permitted by sentence 2 and except for doors serving a single dwelling unit exit doors that are required to swing shall swing in the direction of exit travel.
Corridor fire doors shall be self or automatic closing.
However the doors that serve group b occupancy are permitted to have a lever lock set.
New edition coming soon sign up here to be notified of product release.
If the room load is 60 and i have 2 doors the load on each is 30.